B2AM Innovation Ltd.





















Ammonia switch
OAS-1 reflection based sensor for ammonia



NH3 can be easily detected by classical analytical methods, but in hundreds of agricultural or industrial applications a continuous monitoring is needed. In many cases the precise determination of these compounds is unnecessary, when the concentration reaches a certain level it is sufficient to give an alarm or to switch the ventilation on.

The presence of ammonia in stock-yards and windowless barns may cause serious health problems for the employees and the poultry flock as well. As birds are sensitive to chemical stress, eye-irritation and pulmonary symptoms are likely to happen, when no care is taken to solve the ventilation of the building. It is scientifically proved, that higher ammonia concentrations cause significant decrease in egg-production!

We offer solutions! Our instruments are based on the needs mentioned above. A compact box includes the optical chemical sensors and the built in electronics, which is capable of giving alarm or switch the ventilation system on, when reaching a preset concentration of the analyte.

The dynamic ranges of the instruments are 1-100 ppm for NH3. Although the sensors in the devices have limited lifetimes, the replacement is easy.

The description and recommended applications of the OAS-1 optical ammonia sensor can be downloaded free!

 
Products

Fiber Sensing PRODUCTS

Fiber Sensing

The measurement of convergence, inclination, extension, pressure, displacement, mechanical stress, deformation, based on a new principle, using a fiberoptic setup.

 

FIA
Flow Injection Analyser
B2AM Ltd.

"The FIA analyser is a device for measure several quality and quantity parameters of fluid samples."

(c) comteche.com
CountOx
B2AM Ltd.

"We developed the CountOx system which is capable of continuous monitoring of dissolved oxygen concentrations, even below 10 ppb level."

(c) comteche.com
Uracheck
B2AM Ltd.

"The Uracheck is a luminescent reagent . The reagent was tested on environmental and nuclear power plant samples, although it can be applied for the determination of uranil ions (UO22+) in different groundwater, industrial wastewater, and radioactive samples as low as 0.02 ppb level."

(c) comteche.com

OAS-1 &
OSS-1

B2AM Ltd.

"The OAS-1 and OSS-1 are switches based on optical chemical sensors sensitive for ammonia or carbone-dioxide. They can be used for turning on/off ventillation systems or industrial processes."







2007. (c) All rights reserved.    │   Start page   │   Privacy Policiy   │   Email   │    Design:  Hórusz Európa Bt.
Template: www.alcwebdesign.tk